Uploads by EMysak
Jump to navigation
Jump to search
This special page shows all uploaded files.
Date | Name | Thumbnail | Size | Description | Versions |
---|---|---|---|---|---|
11:09, 4 December 2019 | Siderite, PMA.TIF (file) | 1.85 MB | 1 | ||
08:53, 14 November 2019 | Sillimanite gemstone with organic bands.PNG (file) | 9 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
07:06, 25 October 2019 | Smalt (bottle 491).TIF (file) | 52 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
20:01, 18 June 2020 | Spruce resin.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:47, 11 March 2020 | Starch- liquid laundry starch.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
10:43, 11 March 2020 | Stearic acid (identified by GC MS).TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:58, 14 November 2019 | Strontium Yellow.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
13:00, 14 November 2019 | Sui-sho (Forbes MFA 606), 50X, 532 nm copy.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
08:20, 6 November 2019 | Synthetic Venetian red (Forbes MFA 76) 50X copy.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
13:21, 12 March 2020 | TIF.tif (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
10:17, 11 March 2020 | Table sugar.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 2 | |
11:18, 4 December 2019 | Talc,Harvard Mineral Museum,53201.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
20:03, 18 June 2020 | Talen s Retouching Varnish.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:51, 11 March 2020 | Tannic acid, Chem Service O-108.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
20:10, 18 June 2020 | Thio urea.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
13:18, 14 November 2019 | Ti dioxide (anatase), Forbes.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:20, 20 November 2019 | Ti dioxide (rutile), Forbes 163.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
12:16, 20 November 2019 | Titanium oxide (Forbes MFA 536) copy.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
13:12, 14 November 2019 | Titanium oxide (Forbes MFA 537) copy.tif (file) | 694 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
13:08, 14 November 2019 | Titanium oxide (Forbes MFA 538), 50X, 532 nm copy.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
12:21, 20 November 2019 | Titanium white (Forbes MFA 535) 50X copy.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
10:13, 20 November 2019 | Titanolith (Forbes MFA 532), 50X, 532 nm copy.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
11:04, 20 November 2019 | Titanox (Forbes MFA 539), 50X, 532 nm copy.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
11:50, 20 November 2019 | Titanox A (Forbes MFA 533), 50X, 785 nm copy.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
10:16, 11 March 2020 | Turmeric, ground, McCormick.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
19:52, 24 October 2019 | Turquoise, Reyston NV.PNG (file) | 8 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:37, 6 November 2019 | Ultramarine red, 45.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:35, 6 November 2019 | Ultramarine red (Forbes MFA 45) collodion slide, 532 nm copy.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
20:09, 18 June 2020 | Urea.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:12, 25 October 2019 | Van Dyke Brown, MFA Forbes 15.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:21, 6 November 2019 | Venetian red.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
11:12, 24 October 2019 | Verdigris, dry pigment (Forbes MFA 422), 50X, 532 nm resize.jpg (file) | 63 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
11:30, 4 December 2019 | Vermiculite.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
18:59, 24 October 2019 | Vert Emeraude, FC 407, 532, 10mW.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
19:07, 24 October 2019 | Vert Emeraude, FC 408, 532, 10mW.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
13:31, 24 October 2019 | Vert Veronite FC 390,532nm.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
11:35, 1 October 2019 | Viridian, collodion slide (Forbes MFA 412), 532 nm- resize.tif (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The stone was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A 2... | 1 | |
20:24, 18 June 2020 | Vulcanized rubber, stamped Goodyear 1851.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:48, 11 March 2020 | Wheat starch.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
11:01, 20 November 2019 | Whiting (Forbes MFA no number), collodion slide, 785 nm copy.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
11:23, 12 December 2019 | Witherite, PMA.TIF (file) | 1.85 MB | 1 | ||
11:25, 12 December 2019 | YG95 glass.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:58, 6 November 2019 | Yellow ochre, 269.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
20:26, 18 June 2020 | Zanzibar Copal, Gettens 100.A04 (slope corrected).TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
14:34, 20 November 2019 | Zinc White, Forbes 174.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
18:31, 24 October 2019 | Zinc green (Forbes MFA 354), 50X, 532 nm resize.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
14:40, 20 November 2019 | Zinc oxide (Forbes MFA 530) copy.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
14:39, 20 November 2019 | Zinc white (Forbes MFA 529) collodion slide 785 nm copy.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
14:32, 20 November 2019 | Zinc white (Forbes MFA 531), 50X, 532 nm copy.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
09:32, 14 November 2019 | Zinc yellow, Forbes 59.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 |