14:20, 1 August 2013 | Celadonite(376).PNG (file) | 6 KB | Analyzed on a Nicolet 510P FTIR spectrophotometer with a NicPlan microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-700 cm-1 at a resolution of 4 cm-1. Th... | 1 | |
14:07, 1 August 2013 | Indigo(443).PNG (file) | 8 KB | Analyzed on a Nicolet 510P FTIR spectrophotometer with a NicPlan microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-700 cm-1 at a resolution of 4 cm-1. Th... | 1 | |
13:43, 1 August 2013 | Jade.PNG (file) | 6 KB | Analyzed on a Nicolet 510P FTIR spectrophotometer with a NicPlan microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-700 cm-1 at a resolution of 4 cm-1. Th... | 1 | |
13:30, 1 August 2013 | Lazurite.PNG (file) | 6 KB | Analyzed on a Nicolet 510P FTIR spectrophotometer with a NicPlan microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-700 cm-1 at a resolution of 4 cm-1. Th... | 1 | |
13:19, 1 August 2013 | Malachite(389).PNG (file) | 7 KB | Analyzed on a Nicolet 510P FTIR spectrophotometer with a NicPlan microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-700 cm-1 at a resolution of 4 cm-1. Th... | 1 | |
13:11, 1 August 2013 | Mauve(495).PNG (file) | 7 KB | Analyzed on a Nicolet 510P FTIR spectrophotometer with a NicPlan microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-700 cm-1 at a resolution of 4 cm-1. Th... | 1 | |
13:08, 1 August 2013 | Phthalocyanine blue, forbes 95.PNG (file) | 8 KB | Analyzed on a Nicolet 510P FTIR spectrophotometer with a NicPlan microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-700 cm-1 at a resolution of 4 cm-1. Th... | 1 | |
12:40, 1 August 2013 | Paratacamite.PNG (file) | 6 KB | Analyzed on a Nicolet 510P FTIR spectrophotometer with a NicPlan microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-700 cm-1 at a resolution of 4 cm-1. Th... | 1 | |
12:16, 1 August 2013 | Phthalocyanine Green.PNG (file) | 7 KB | Analyzed on a Nicolet 510P FTIR spectrophotometer with a NicPlan microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-700 cm-1 at a resolution of 4 cm-1. Th... | 1 | |
12:09, 1 August 2013 | Pompeian Blue.PNG (file) | 6 KB | Analyzed on a Nicolet 510P FTIR spectrophotometer with a NicPlan microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-700 cm-1 at a resolution of 4 cm-1. Th... | 1 |