Uploads by EMysak
Jump to navigation
Jump to search
This special page shows all uploaded files.
Date | Name | Thumbnail | Size | Description | Versions |
---|---|---|---|---|---|
07:16, 11 March 2020 | Acacia arabica (HU Bot. Museum 7655).TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
06:57, 18 June 2020 | Agar-Agar, Gettens 100.B48.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
10:17, 25 October 2019 | Alizarin 2.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
12:10, 1 October 2019 | Alizarin Green, Forbes 414.PNG (file) | 10 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 2 | |
10:21, 25 October 2019 | Alizarin lake dark (Forbes MFA 27) resize.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
15:43, 20 November 2019 | Alum.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
10:07, 10 March 2020 | Ametrine, purple, 785, 100.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
10:08, 10 March 2020 | Ametrine, yellow, 785, 100.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
15:44, 20 November 2019 | Anglesite PMA.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
15:45, 20 November 2019 | Anhydrite PMA.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:39, 3 March 2020 | Aniline Black, PBlk 001.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:49, 26 November 2019 | Ankerite PMA.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:04, 26 November 2019 | Anorthite PMA.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:06, 26 November 2019 | Anorthoclase PMA.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 2 | |
10:56, 24 October 2019 | Antigorite.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
12:14, 1 October 2019 | Antlerite.TIF (file) | 65 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:27, 26 November 2019 | Antlerite PMA.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:53, 14 November 2019 | Aragonite (HU Min. Museum 116189), 50X, 785 nm copy.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
09:51, 14 November 2019 | Aragonite 2.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 2 | |
08:19, 25 October 2019 | Asphaltum, Forbes Raw Materials.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
11:13, 1 October 2019 | Atacamite.TIF (file) | 61 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:42, 4 December 2019 | Attapulgite, Grimaldi.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:30, 26 November 2019 | Attapulgite.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
07:07, 29 October 2019 | Aureolin (Forbes MFA 342), collodion slide 785 nm resize.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
07:04, 29 October 2019 | Aureolin 342.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
12:44, 1 October 2019 | Azurite, cupric carbonate, 8.01.14.TIF (file) | 60 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
12:52, 1 October 2019 | Azurite (Forbes MFA 452), 532 nm.TIF (file) | 1.86 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The stone was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A 2... | 1 | |
09:45, 26 November 2019 | BRUCITE PMA.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
07:00, 18 June 2020 | Baltic amber.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
10:10, 14 November 2019 | Barium sulfate (525).TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
10:06, 14 November 2019 | Barium sulfate (Forbes MFA 525) collodion slide, 785 nm copy.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
08:35, 25 October 2019 | Biotite from granite.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:52, 25 October 2019 | Bistre, MFA Forbes 18.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
07:25, 11 March 2020 | Black cherry gum, 1975 (HUAM, CCT S).TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
13:10, 1 October 2019 | Blue verditer, collodion slide (Forbes MFA 436), 532 nm.TIF (file) | 1.91 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The stone was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A 2... | 1 | |
09:32, 26 November 2019 | Bone ash, vial 540.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
10:40, 11 March 2020 | British Museum Leather Dressing, Cons.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
13:21, 1 October 2019 | Brochantite.TIF (file) | 68 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:33, 15 October 2019 | Brochantite (bottle 385).TIF (file) | 58 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:03, 4 December 2019 | CaSO4 hemihydrate.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:50, 29 October 2019 | Cadmium (Forbes MFA 318) resize.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
07:44, 29 October 2019 | Cadmium Barium red (Forbes MFA 172), 785nm resize.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
11:26, 29 October 2019 | Cadmium Lemon -319, 785,100mW.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
09:05, 29 October 2019 | Cadmium Red 125.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
07:02, 30 October 2019 | Cadmium Yellow -316, 785, 100mW.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
07:05, 30 October 2019 | Cadmium Yellow -320, 785,100 mW.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
07:10, 30 October 2019 | Cadmium Yellow Lt, -321 (not CdS).TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
09:40, 29 October 2019 | Cadmium orange (Forbes MFA 210) resize.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
10:08, 29 October 2019 | Cadmium sulfide 179.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:56, 29 October 2019 | Cadmium yellow (Forbes MFA 315), 785nm resize.tif (file) | 695 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 |