https://cameo.mfa.org/index.php?title=File:Slide38_F484.PNG&feed=atom&action=history File:Slide38 F484.PNG - Revision history 2024-03-28T22:56:05Z Revision history for this page on the wiki MediaWiki 1.35.3 https://cameo.mfa.org/index.php?title=File:Slide38_F484.PNG&diff=40428&oldid=prev AMcQ: Analyzed on Bruker AXS ARTAX µXRF spectrophotometer using ARTAX spectra version 5.3.15.1. It is an open architecture model on a tripod equipped with a Rhodium tube with a beryllium window and a 650 micron collimator and no filter. Energy range is 0-... 2013-10-07T14:00:59Z <p>Analyzed on Bruker AXS ARTAX µXRF spectrophotometer using ARTAX spectra version 5.3.15.1. It is an open architecture model on a tripod equipped with a Rhodium tube with a beryllium window and a 650 micron collimator and no filter. Energy range is 0-...</p> <p><b>New page</b></p><div>Analyzed on Bruker AXS ARTAX µXRF spectrophotometer using ARTAX spectra version 5.3.15.1. It is an open architecture model on a tripod equipped with a Rhodium tube with a beryllium window and a 650 micron collimator and no filter. Energy range is 0-50 KeV with a max voltage of 40kV and max current of 700µA. The scan time of 3 minutes. Note: The blanks show the glass slide substrates for the Forbes samples may contain measurable levels of arsenic, calcium, potassium, and/or zirconium.</div> AMcQ