Difference between revisions of "Madder (Indian madder, Rubia cordifolia) LC"

From CAMEO
Jump to navigation Jump to search
Line 33: Line 33:
 
= Chromatograms =
 
= Chromatograms =
  
HPLC profiles for Rubia akane. Elution was monitored at 450 nm. The numbers over the peaks are the molecule masses of the principal of otherwise significant components [1].
+
HPLC profiles for Rubia cordifolia. Elution was monitored at 450 nm. The numbers over the peaks are the molecule masses of the principal of otherwise significant components [1].
  
[[File:Rubia akane LC.PNG|center|frame|Absorbance at 450nm (mAU)]]
+
[[File:Indian madder.PNG|center|frame|Absorbance at 450nm (mAU)]]
  
  

Revision as of 11:03, 17 July 2017

Indian madder from Tanakao-Nao, Japan/ Photo by X. Zhang/

Description

Historical importance

Summary of results

Analytical instrumentation and procedures

Extraction of plant material

Samples of plant specimens were extracted by heating about 10 mg of the ground or chopped, dry plant with 1.0 mL of methanol/water (1:1) at 65 °C for 1 h. The supernatant liquid was removed by pipet and was centrifuged at 12,000 rpm for about 5 min, after which the clear supernatant was subjected to analysis. This solution was diluted with methanol/water (1:1) if necessary.

Extraction of dyed textiles or fibers

Dyed textile or yarn specimens were extracted using a “soft” procedure, namely, by heating approximately 0.1–1 mg of fibers in 200 μL of a solution of pyridine/water/1.0 M oxalic acid in water (95:95:10) at 100 °C for 15 min.

HCl treated

The plant extracts were heated in 2 M HCl at 95 °C for 60 min to hydrolyze O-glycosides or to promote decarboxylation.

Analysis of dye components

Extracts of plant material or of dyed silk or wool were analyzed by HPLC with photodiode array and mass spectrometric detection using an Agilent 1100 high performance liquid chromatography system consisting of an automatic injector, a gradient pump, a Hewlett-Packard series 1100 photodiode array detector, and an Agilent series 1100 VL on-line atmospheric pressure ionization electrospray ionization mass spectrometer. Operation of the system and data analysis were done using ChemStation software, and detection was generally done in the negative ion [M-H]– mode. Separation of dye components was made, in the majority of cases, on a Vydac C18 reversed phase column (2.1 µm dia.×250 µm long; 5-µm particle size). Columns were eluted with acetonitrile-water gradients containing 0.1 % formic acid in both solvents.

Chromatograms

HPLC profiles for Rubia cordifolia. Elution was monitored at 450 nm. The numbers over the peaks are the molecule masses of the principal of otherwise significant components [1].

Absorbance at 450nm (mAU)


Sample information

compounds found in extracts of various species of Rubia or Rubia-dyes textiles. By R. A. Laursen, Boston University

Identified compounds



References

[1] [2] [3]