Uploads by EMysak
Jump to navigation
Jump to search
This special page shows all uploaded files.
Date | Name | Thumbnail | Size | Description | Versions |
---|---|---|---|---|---|
10:13, 1 October 2019 | Atacamite.TIF (file) | 61 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
10:35, 1 October 2019 | Viridian, collodion slide (Forbes MFA 412), 532 nm- resize.tif (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The stone was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A 2... | 1 | |
11:10, 1 October 2019 | Alizarin Green, Forbes 414.PNG (file) | 10 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 2 | |
11:14, 1 October 2019 | Antlerite.TIF (file) | 65 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
11:23, 1 October 2019 | Pompeian blue, Le Franc 1929, 8.01.1.TIF (file) | 54 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
11:26, 1 October 2019 | Pompeian Blue, dry pigment (Forbes MFA 467), 532 nm.TIF (file) | 1.91 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The stone was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A 2... | 1 | |
11:44, 1 October 2019 | Azurite, cupric carbonate, 8.01.14.TIF (file) | 60 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
11:52, 1 October 2019 | Azurite (Forbes MFA 452), 532 nm.TIF (file) | 1.86 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The stone was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A 2... | 1 | |
12:10, 1 October 2019 | Blue verditer, collodion slide (Forbes MFA 436), 532 nm.TIF (file) | 1.91 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The stone was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A 2... | 1 | |
12:21, 1 October 2019 | Brochantite.TIF (file) | 68 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
12:41, 1 October 2019 | Celadonite, collodion slide (Forbes MFA 376), 532nm.TIF (file) | 1.91 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
08:25, 8 October 2019 | Cerulean blue, collodion slide (Forbes MFA 434), 50X, 532 nm.TIF (file) | 1.91 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
08:30, 8 October 2019 | Chalconatronite, collodion slide, 532nm.TIF (file) | 1.91 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
08:35, 8 October 2019 | Chalcanthite, PMAI0528, -R6153-1.TIF (file) | 1.85 MB | 1 | ||
08:40, 8 October 2019 | Chrome green, collodion slide Forbes (MFA 350), 532 nm.TIF (file) | 1.91 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
09:00, 8 October 2019 | Chrysocolla, Gila County AZ.PNG (file) | 7 KB | 1 | ||
08:43, 10 October 2019 | Cobalt blue (bottle 484).TIF (file) | 47 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:12, 10 October 2019 | Cobalt blue, Forbes 476, 532 nm.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
09:25, 10 October 2019 | Cobalt blue, Forbes 477, 532 nm.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
09:58, 10 October 2019 | Chromium Oxide Green (MFA Forbes 64).TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
10:11, 10 October 2019 | Cobalt violet (Forbes MFA 498), 50X, 532 nm.TIF (file) | 1.91 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
10:14, 10 October 2019 | Cobalt violet dark (Forbes MFA 498), 785nm resize.tif (file) | 70 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
10:17, 10 October 2019 | Cobalt violet light, collodion slide (Forbes MFA 501), 532 nm.TIF (file) | 1.91 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
07:50, 15 October 2019 | Cupric sulfate.TIF (file) | 55 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
07:53, 15 October 2019 | Copper chlorides, mostly atacamite.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:10, 15 October 2019 | Emerald Green, FC 393, 532nm.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
08:12, 15 October 2019 | Emerald Green FC 395, 532nm.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
08:20, 15 October 2019 | Emerald Green FC 396, 532nm, 20mw.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
08:21, 15 October 2019 | Emerald Green FC 392, 532nm.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
08:25, 15 October 2019 | Epidote, Prince of Wales Island.PNG (file) | 8 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 2 | |
08:27, 15 October 2019 | Fayalite, Upper Bear Creek CO.PNG (file) | 7 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:33, 15 October 2019 | Brochantite (bottle 385).TIF (file) | 58 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
08:44, 15 October 2019 | Glauconite, Harvard Mineralogical Museum.PNG (file) | 9 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:01, 15 October 2019 | Green Earth, Terre Verde, Forbes 367.PNG (file) | 8 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:02, 15 October 2019 | Green earth, Terre verte, Roberson, 1926 (bottle 376- celadonite)).TIF (file) | 54 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
07:34, 16 October 2019 | Indigo, Forbes (MFA 443), 785nm.TIF (file) | 1.91 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
07:39, 16 October 2019 | Cuprite, ground (HU Mineral Museum 129900).TIF (file) | 1.91 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 785 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
08:01, 16 October 2019 | French Ultramarine, SEM stub (Forbes MFA 473), 50X, 532 nm.TIF (file) | 1.91 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
08:07, 16 October 2019 | Natural ultramarine, Forbes 465 (MFA), blue particle, 532nm.TIF (file) | 1.91 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
08:24, 16 October 2019 | Jade, green, large block.TIF (file) | 54 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:04, 24 October 2019 | Malachite, FC 389, 532nm.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
09:08, 24 October 2019 | Malachite (bottle 389).TIF (file) | 59 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:26, 24 October 2019 | Malachite, SEM stub (Forbes MFA 385), 50X, 532 nm.TIF (file) | 1.91 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
09:37, 24 October 2019 | Prussian Blue (448).PNG (file) | 8 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:44, 24 October 2019 | Serpentine, 50 X mag, MFA 20.233.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
09:56, 24 October 2019 | Antigorite.TIF (file) | 1.85 MB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
09:58, 24 October 2019 | Mauve (bottle 495) Weber 1942.TIF (file) | 56 KB | Analyzed on a Nicolet iS10 FTIR spectrophotometer with a Nicolet Continuum microscope using Omnic 32 (version 6.0) software. Sample pressed on microdiamond cell and analyzed with transmitted radiation over a range of 4000-650 cm-1 at a resolution of 4... | 1 | |
10:05, 24 October 2019 | Scheele's green (Forbes 9.06.3) resize.jpg (file) | 50 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
10:12, 24 October 2019 | Verdigris, dry pigment (Forbes MFA 422), 50X, 532 nm resize.jpg (file) | 63 KB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 | |
12:31, 24 October 2019 | Vert Veronite FC 390,532nm.TIF (file) | 1.85 MB | Analyzed using Bruker Senterra instrument with Opus 5.5 software. The pigment was analyzed using 532 nm laser at a power setting of 10 over a wavelength range of 65-1555 cm-1 and resolution of 3-5 cm-1. The spectrum was integrated for 100 seconds. A... | 1 |