− | + | EDS Spectrum showing elemental peak height as a function of X-ray counts collected (LC) | |
+ | |||
+ | Elements Identified | ||
+ | Major (> 10%): carbon, oxygen, iron. | ||
+ | Minor (1-10%): calcium, silicon, sulfur, magnesium, aluminum. | ||
+ | Trace (< 1%): potassium, phosphorus. | ||
+ | |||
+ | Area X-ray counts collected: 1,010,708. | ||
+ | Live Time: 19.0 seconds. | ||
+ | Magnification: 2608x. | ||
+ | Analyzed using Oxford X-Max80 energy-dispersive X-Ray spectroscopy (EDS) and Oxford AZtec platform software. Pigment sample was applied to carbon tape and mounted onto aluminum examination stub. X-rays from sample were excited by a 20 kV SEM electron beam in a low vacuum chamber (10 Pascals). The resolution of the X-Max80 silicon drift detector is 123 eV at MnKα wavelength. |
Latest revision as of 16:00, 29 June 2017
EDS Spectrum showing elemental peak height as a function of X-ray counts collected (LC)
Elements Identified Major (> 10%): carbon, oxygen, iron. Minor (1-10%): calcium, silicon, sulfur, magnesium, aluminum. Trace (< 1%): potassium, phosphorus.
Area X-ray counts collected: 1,010,708. Live Time: 19.0 seconds. Magnification: 2608x. Analyzed using Oxford X-Max80 energy-dispersive X-Ray spectroscopy (EDS) and Oxford AZtec platform software. Pigment sample was applied to carbon tape and mounted onto aluminum examination stub. X-rays from sample were excited by a 20 kV SEM electron beam in a low vacuum chamber (10 Pascals). The resolution of the X-Max80 silicon drift detector is 123 eV at MnKα wavelength.