Difference between revisions of "Lithium chloride hygrometer"

From CAMEO
Jump to navigation Jump to search
(username removed)
 
 
Line 3: Line 3:
 
A formerly used type of hygrometer that measured humidity based on the function of temperature and electrical conductivity of a hygroscopic salt.  Most lithium chloride hygrometers contain a bundle of glass fibers coated with a dry film of lithium chloride salt.  The fibers are wrapped with metal wires connected to a continual ac source.  When the fibers are dry they are nonconductive.  When the fiber surfaces absorb moisture, they become conductive allowing a current to pass through the wire.  This current heats the fibers which in turn drives off the moisture from the salt.  Thus the wires are kept at the temperature required to just maintain dryness.  This temperature can be directly converted to humidity.  Lithium chloride hygrometers can take 3-10 minutes to respond to environmental changes (Thomson 1978).  They require a continual electrical source.
 
A formerly used type of hygrometer that measured humidity based on the function of temperature and electrical conductivity of a hygroscopic salt.  Most lithium chloride hygrometers contain a bundle of glass fibers coated with a dry film of lithium chloride salt.  The fibers are wrapped with metal wires connected to a continual ac source.  When the fibers are dry they are nonconductive.  When the fiber surfaces absorb moisture, they become conductive allowing a current to pass through the wire.  This current heats the fibers which in turn drives off the moisture from the salt.  Thus the wires are kept at the temperature required to just maintain dryness.  This temperature can be directly converted to humidity.  Lithium chloride hygrometers can take 3-10 minutes to respond to environmental changes (Thomson 1978).  They require a continual electrical source.
  
== Additional Information ==
+
==Resources and Citations==
  
G.Thomson, The Museum Environment,  Butterworths, London, 1978.
+
* G.Thomson, The Museum Environment,  Butterworths, London, 1978.
  
 
[[Category:Materials database]]
 
[[Category:Materials database]]

Latest revision as of 14:30, 14 September 2022

Description

A formerly used type of hygrometer that measured humidity based on the function of temperature and electrical conductivity of a hygroscopic salt. Most lithium chloride hygrometers contain a bundle of glass fibers coated with a dry film of lithium chloride salt. The fibers are wrapped with metal wires connected to a continual ac source. When the fibers are dry they are nonconductive. When the fiber surfaces absorb moisture, they become conductive allowing a current to pass through the wire. This current heats the fibers which in turn drives off the moisture from the salt. Thus the wires are kept at the temperature required to just maintain dryness. This temperature can be directly converted to humidity. Lithium chloride hygrometers can take 3-10 minutes to respond to environmental changes (Thomson 1978). They require a continual electrical source.

Resources and Citations

  • G.Thomson, The Museum Environment, Butterworths, London, 1978.