Difference between revisions of "File:1 01 9 BoneAsh EDS Spectrum.jpg"

From CAMEO
Jump to navigation Jump to search
(EDS Spectrum showing elemental peak height as a function of X-ray counts collected (LC) Elements Identified Major (> 10%): oxygen, carbon, calcium, phosphorus Minor (1-10%): NA Trace (< 1%): magnesium Area X-ray counts collected: 1,051,106 Live Tim...)
 
 
Line 2: Line 2:
  
 
Elements Identified
 
Elements Identified
Major (> 10%): oxygen, carbon, calcium, phosphorus  
+
Major (> 10%): oxygen, carbon, calcium, phosphorus.
Minor (1-10%): NA
+
Minor (1-10%): NA.
Trace (< 1%): magnesium
+
Trace (< 1%): magnesium.
  
Area X-ray counts collected: 1,051,106
+
Area X-ray counts collected: 1,051,106.
Live Time: 30.8 seconds
+
Live Time: 30.8 seconds.
Magnification: 500x
+
Magnification: 500x.
 
Analyzed using Oxford X-Max80 energy-dispersive X-Ray spectroscopy (EDS) and Oxford AZtec platform software. Pigment sample was applied to carbon tape and mounted onto aluminum examination stub. X-rays from sample were excited by a 20 kV SEM electron beam in a low vacuum chamber (10 Pascal). The resolution of the X-Max80 silicon drift detector is 123 eV at MnKα wavelength.
 
Analyzed using Oxford X-Max80 energy-dispersive X-Ray spectroscopy (EDS) and Oxford AZtec platform software. Pigment sample was applied to carbon tape and mounted onto aluminum examination stub. X-rays from sample were excited by a 20 kV SEM electron beam in a low vacuum chamber (10 Pascal). The resolution of the X-Max80 silicon drift detector is 123 eV at MnKα wavelength.

Latest revision as of 09:11, 10 January 2017

EDS Spectrum showing elemental peak height as a function of X-ray counts collected (LC)

Elements Identified Major (> 10%): oxygen, carbon, calcium, phosphorus. Minor (1-10%): NA. Trace (< 1%): magnesium.

Area X-ray counts collected: 1,051,106. Live Time: 30.8 seconds. Magnification: 500x. Analyzed using Oxford X-Max80 energy-dispersive X-Ray spectroscopy (EDS) and Oxford AZtec platform software. Pigment sample was applied to carbon tape and mounted onto aluminum examination stub. X-rays from sample were excited by a 20 kV SEM electron beam in a low vacuum chamber (10 Pascal). The resolution of the X-Max80 silicon drift detector is 123 eV at MnKα wavelength.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current12:53, 4 January 2017Thumbnail for version as of 12:53, 4 January 20171,460 × 441 (65 KB)MKullman (talk | contribs)EDS Spectrum showing elemental peak height as a function of X-ray counts collected (LC) Elements Identified Major (> 10%): oxygen, carbon, calcium, phosphorus Minor (1-10%): NA Trace (< 1%): magnesium Area X-ray counts collected: 1,051,106 Live Tim...

The following page uses this file:

Metadata