Difference between revisions of "Berberis dye (berberis Julianae) LC"
(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
− | [[File: | + | [[File:Berberis jullanae.jpg|thumb|''Berberis julianae'' bush, photo by X. Zhang at the Arnold Arboretum, Boston]] |
== Description == | == Description == | ||
Line 14: | Line 14: | ||
== Analytical instrumentation and procedures == | == Analytical instrumentation and procedures == | ||
+ | HPLC-DAD-MS analysis was performed with an Agilent 1100 liquid chromatography system consisting of an automatic injector, a gradient pump, a HP series 1100 DAD, and an Agilent series 1100 VL on-line atmospheric pressure ionization electrospray ionization mass spectrometer. Separations were done on a Vydac 214TP52 analytical column (2.1 mm diameterX250 mm; 5-ím particle size). The column was eluted at a flow rate of 0.2 mL/min with a tertiary gradient of water (A),acetonitrile (B), and 1% (v/v) aqueous formic acid (C) with the following elution program: 0 min, 90% A, 5% B, 5% C; 0-55 min, a linear gradient to 35% A, 60% B, 5% C; 55-60 min, a linear gradient elution to 15% A, 80% B, 5% C; 60-62 min, isocratic elution at 15% A, 80% B, 5% C; 62-70 min gradient elution to 90% A, 5% B, 5% C; and reequilibration with the latter solvent for 15 min. The mass spectrometer was run both in the negative and positive ion mode. | ||
== Chromatograms == | == Chromatograms == |
Latest revision as of 08:20, 29 September 2017
Description
Berberis julianae, also called Mahonia julianae, is a flowering evergreen shrub native to Central China. It is widely grown as an ornamental in other temperate regions. It grows to 6' to 8' tall and 4' to 6' wide.
Historical importance
Summary of results
Analytical instrumentation and procedures
HPLC-DAD-MS analysis was performed with an Agilent 1100 liquid chromatography system consisting of an automatic injector, a gradient pump, a HP series 1100 DAD, and an Agilent series 1100 VL on-line atmospheric pressure ionization electrospray ionization mass spectrometer. Separations were done on a Vydac 214TP52 analytical column (2.1 mm diameterX250 mm; 5-ím particle size). The column was eluted at a flow rate of 0.2 mL/min with a tertiary gradient of water (A),acetonitrile (B), and 1% (v/v) aqueous formic acid (C) with the following elution program: 0 min, 90% A, 5% B, 5% C; 0-55 min, a linear gradient to 35% A, 60% B, 5% C; 55-60 min, a linear gradient elution to 15% A, 80% B, 5% C; 60-62 min, isocratic elution at 15% A, 80% B, 5% C; 62-70 min gradient elution to 90% A, 5% B, 5% C; and reequilibration with the latter solvent for 15 min. The mass spectrometer was run both in the negative and positive ion mode.
Chromatograms
Identified compounds
Compound | RT (min.) | MW | UV/vis | Other |
---|---|---|---|---|
Jatrorrhizine | 29.4 | 337 | 344,426 | |
Berberine | 32.7 | 335 | 344,426 | co-elutes with palmatine |
Palmatine | 32.7 | 351 | 344,426 | co-elutes with berberin |
References